Using JMRI with NCE Power Cab, SB5 and PH-Power Pro
JMRI works very well with NCE (Power Cab, SB3/5 and Power Pro). The NCE USB is the ONLY way to connect a Power Cab or SB3/5 to a computer.
DO NOT USE AN NCE USB TO CONNECT TO A POWER PRO. It will not do what you want JMRI to do. Use a USB to Serial cable to connect your computer to the Power Pro Learn more here
NCE USB Interface
Make sure you always use the latest version of JMRI.
Download and install SiLabs CP210x drivers for the NCE USB from <http://www.silabs.com/products/mcu/Pages/USBtoUARTBridgeVCPDrivers.aspx>
There has been some confusing documentation about jumper settings for a V7 NCE USB. The following are the CORRECT settings for JMRI with various NCE USB versions and NCE hardware combinations.
The correct settings for a Power Cab V1.65 or V1.28 (as shown when the Power Cab starts up) and an NCE USB V6 (or you are not sure of the USB version) are:
- All USB Jumpers off (or at least 2, 3 & 4. Jumper 1 is ignored).
- JMRI preferences are:
- System manufacturer: NCE
- System connection: NCE USB
- Serial port: <whatever is appropriate for your system>
- USB version: V6.x.x
- System: Power Cab
- Additional Connection Settings->Baud rate: 9600.
- The JMRI console log should then report V6.3.0.
If it reports V7.3.0 and your Power Cab is V1.65, use the settings below instead.
The correct settings for a Power Cab V1.65 and an NCE USB V7 are:
- All USB Jumpers on (or at least 2, 3 & 4. Jumper 1 is ignored).
- JMRI preferences are:
- System manufacturer: NCE
- System connection: NCE USB
- Serial port: <whatever is appropriate for your system>
- USB version: V7.x.x
- System: Power Cab
- Additional Connection Settings->Baud rate: 19200.
- The JMRI console log should then report V7.3.7.
The correct settings for an SB5 and an NCE USB V7 are:
- USB Jumper 4 on. All others off (or at least 2 & 3. Jumper 1 is ignored).
- JMRI preferences are:
- System manufacturer: NCE
- System connection: NCE USB
- Serial port: <whatever is appropriate for your system>
- USB version: V7.x.x
- System: SB5
- Additional Connection Settings->Baud rate: 19200.
- The JMRI console log should then report V7.3.1.
If this does not work, either:
- use Help->System console...->Copy to clipboard and paste into a post https://groups.yahoo.com/neo/groups/NCE-DCC/info
- use Help->Upload Debugging Info... and tell https://groups.yahoo.com/neo/groups/NCE-DCC/info . The JMRI developers on the NCE Yahoo! group can then look in the reports. Your computer will need an Internet connection to do this.
Thank you to The NCE-DCC list Yahoo Group and Dave Heap
For more information and to join, go to https://groups.yahoo.com/neo/groups/NCE-DCC/info