Dual Decoder Installations
Buy Decoders
Many DCC users are incorporating two decoders
for some of their installations. The Soundtraxx DSX sound only DCC
decoder has not only been popular with large scale users seeking
sound but also with many HO modelers putting the DSX in the tender
and another in the loco. Also modelers are now using "function
only" decoders to provide for more lighting effects. While
two decoders can give you more goodies, there can be unforeseen
problems! Don Fiehmann has drafted this guide to help you
out.
Why Two Decoders
Today decoders have included many impressive new features along
with improved performance. Some decoders are better at Back-EMF
and others have sound only with no motor control, like the SoundTraxx
DSX series. We want to get the best for our locomotives and this
leaves us with a problem of which decoder to install. One way to
get the best performance is to combine the best features of two
decoders into one engine. If the engine is too small to install
sound, you may put the sound decoder into a car that follows behind
the engine. Another reason for dual decoders is to have one decoder
for motor control and the other for added lighting functions. One
place where two decoders can be used is with an A and B unit that
both have their own decoders and are permanently consisted.
The NMRA DCC standards state that if a decoder CV
is addresses and the decoder does not use that specific CV, the
decoder should not respond. This lets you modify a CV that is used
by one decoder and not the other decoder. This may work most of
the time, but there is always the chance that both decoders do use
the same CV number and you end up changing both decoders. One you
want to change one and the other you may not want to change. You
can make changes to both decoders at the same time on things like
CV-3 and CV-4 for acceleration and deceleration. These can be changed
with OPS mode programing.
Installing two decoders is not a hard project. You
can have the two decoders use separate addresses. This allows you
to separately control and modify either of the decoders. This also
means to operate the features you need to switch addresses. You
also have to remember the dual addresses. A better way is to control
both decoders by setting them to the same address. Then the locomotive
uses a single address to activate the functions of either decoder.
But there is a problem when setting CVs in one of the decoders and
not affecting the other decoders.
Setting Up Two Decoders
There are some problems when setting up two decoders at the same
time with the same address. If you use the program track for two
decoders, they can overload the command stations limited power
to the program track. This will cause either a CANT
READ CV or can even detect the two decoders as a short circuit.
Another problem comes up when you are setting values in the CVs.
There are ways to do setups or make changes to the CVs in a decoder
A without affecting decoder B or B
with affecting A. There is more than one way to control
which decoders CVs you wish to modify.
Lock Feature
There is a proposal by Digitrax to the NMRA DCC Working Group to
be able to control which decoder to modify while the other decoder
is locked. The lock uses a pair of CVs in each decoder. This is
only a proposal and the only decoders I know of that have this feature
is the Digitrax DH163 series and the new SoundTraxx Tsunami. This
feature requires both decoders have the Lock feature to work.

Lock Substitute Scheme
There was a hint on the Internet on setting up two decoders that
was very clever. This scheme works a little like the lock feature,
but without the special lock feature. It used a combination of 2
digit and 4 digit addressing. Two digit addresses are setup separately
before the decoders are installed. When CV-29 is set for 4 digit
addressing, both decoders respond When CV-29 is set for 2 digit
addressing, each decoder can be addressed separately using the 2
digit address with OPS mode programming. Here is how the decoders
are setup. I tested this using an NCE decoder and a SoundTraxx DSX
decoder. One advantage of this scheme is you dont have to
remove the body shell to make changes to CVs.
| Address |
Decoder A (Motor) |
Decoder B (Sound) |
| 2 Digit |
CV-1 = 1 |
CV-1 = 2 |
| 4 Digit |
CV-17/18 =1234 |
CV-17/18 = 1234 |
|
The addresses used are just samples.
Setting up CV 29.
Bit 5 (Value 32) in CV29 controls the 2/4 digit addressing, on for
4 digit and off for 2 digit. Most also use the 28 speed step option,
bit 1 (Value 2) if you add the two together the total is 34
for 4 digit, and 2 for 2 digit addressing. (Other bits can
be added to CV-29 for other features. See the chart below.)
Setting up the Dual Decoders
These steps work best using a decoder tester like the NCE decoder
tester.
(1) Setup the two decoders separately on the program track. Use
address 1" for the motor control decoder and 2"
for the second decoder. Avoid using 3" as this is the
default value. (2) Setup the same 4 digit address for both decoders.
(3) Customize other CVs as needed. (4) Install the decoders.
Changing CVs
To change one of the decoders, with OPS mode use the 4 digit address
to program the value in CV-29 to 2". Use the 2 digit
address of 1 or 2, to program the CVs in each of the separate decoders.
To return to 4 digit addressing you need to return the value in
CV-29 of both decoders using OPS mode and the separate two digit
addresses (1 and 2).


CV-29 Bit functions Chart (Not all decoders have all of these features.)
| Bit |
Value |
Function the bit controls |
| 0 |
1 |
Normal Direction of Travel (NDOT) ON for reverse |
| 1 |
2 |
OFF for 14 speed steps, ON for 28 Speed Steps |
| 2 |
4 |
OFF will not run on dc power, ON to run on dc power, |
| 3 |
8 |
ON for advance acknowledgment |
| 4 |
16 |
OFF for standard speed table, ON for alternate table
|
| 5 |
32 |
OFF for 2 digit address, ON for 4 digit address. |
|
Separate Wiring Method
Two decoders can be separately programed before installation and
then wired together. The problem with this method is once they are
wired and installed changes may be needed. How do you make a change
in one without the possibility of also making changes to the other
decoder? Connectors can be installed to make it easy to electrically
separate the two decoders for safe programing.
Diesels
The easiest way is to use small connectors like the two wire Miniatronics
connectors. The two decoders can be separated by disconnecting the
connectors. With the connectors disconnected decoder 1 can be programed
by putting the engine on the program track or using OPS mode programming.
To program decoder 2 make a jumper from a matching half of the 2
pin connector. Connect a pair of alligator clips to the wires. When
the decoders are disconnected, the jumper can be used to connect
decoder 2 to the program track rails via the jumper cable.
Once installed you can unplug the connector to safely
program decoder 1. To program decoder 2 make a jumper cable that
can be plugged into the male connector of decoder 2. Connect the
jumper to the rails. Remember to remove the locomotive from the
rails to disconnect decoder 1. Now decoder 2 can be programmed safely.

Dual Units
For more reliable operation with an A and B unit connector a two
pin connector can be run between the two units. The Miniatronics
connectors are small and almost hidden when installed. I have a
pair of F7s where the two wire connector fits in the widows of the
doors between the two diesels. It is hardly visible and easily disconnected.
Steam
Steam engines normally use the engine to pick up power from the
engineers side and the tender from the firemans side.
To power a decoder in either the engine and/or tender, an extra
wire is needed between the two. Some steam engines have the wireless
draw-bar that is not always a reliable connection. With least one
additional wire needed, a connector for both wires should be used
for more reliable operation. If dual decoders are installed and
more connections needed Miniatronics has 2,3, and 4 wire connectors.
It is normally easy to find room in the tender for
a decoder, but the engine is another story. With the newer smaller
decoders, they can fit under the cab roof or in the boiler. Some
weight may have to be removed to make room for the decoder. Be sure
to insulate the decoder to prevent shorts.

Up to 4 wires are available with
Miniatronics connectors.
White dot helps when plugging together.
Test Installation
I have an Akane brass cab-forward that has been re-motored with
a can motor. A Lenz decoder was installed because of its small size
and excellent Back-EMF characteristic. To add sound a SoundTraxx
DSX decoder was selected. There was plenty of room in the tender
for the speaker and decoder.
One of the rail power feeds is normally transferred
from the tender to the engine via the wireless draw-bar.
To power the DSX decoder in the tender a wire is needed for the
other rail connection from the locomotive. For a more reliable connection
a two wire Miniatronics connector was run between the engine and
tender so both the locomotive and the tender had connections to
both rails.

The 2 wire connector is below the
wireless connector.
Cab-forwards are oil fired so there is no coal
load to hid the speaker. The best place for the speaker was the
floor of the tender. A weight in the center of the tender had to
be removed to make room for an oval speaker. The weight was cut
in two and each part mounted on the ends of the tender floor. A
series of holes was drilled in the area below the speaker location.
The DSX decoder was attached on top the speaker using form tape.
Before connecting the two decoders together I programmed
the decoders with a short address of 1" for the Lenz
and 2" for the DSX. The decoders were then programmed
for a long address of 4177 to match the engine number.

Decoder mounted on top of the speaker
with foam tape.
Sound was much louder with the shell on.
In the first test I left the tender shell off. The
volume was low and so I programed the DSX for maximum volume. I
also was able change the chuff rated to match the engine wheel revolutions.
I could run the engine using address 1 and change the CV in the
DSX using address 2 until I got a close match. Speed steps have
to be the same in both decoders when matching the chuffs to wheel
revolutions. Then I changed the addresses back to the four digit
address (4177) for normal operation.
The big surprise was when the tender shell was installed
over the tender floor. The sound level increased substantially,
so much that I had to reduce the volume!
The 4177 is now in service pulling a string of PFE
refers in a train known as the Fruit Block.
Key Mapping
With dual decoders you may need more functions operate with a single
function key. One application would be the horn/whistle operates
in one decoder while the other decoder runs two outputs as ditch
lights. I did this as a test using a pair of F7s with the light
control in the A unit and the sound in the B unit. For this test
I connected to two number board lights in the A unit as ditch
lights. The A unit key mapping was changed so the whistle
key would also activate the two outputs connected to the number
board lamps. These outputs CVs also needed to be setup to act as
ditch lights. (Are ditch lights prototype on an F7? Yes, I have
seen ditch lights on an F7.) When the whistle key was operated,
the horn would sound and the lights would start flashing for a period
of time set by a CV. When finish the lights would go back on.

Key mapping works by using CVs 33 to 46 as a matrix.
Each CV in this group controls one output line. The bits that are
turned on in the CVs control which function key(s) will turn on
the output line.
Here is the sequence of operation. The decoder is
given a function key instruction (1.) The signal is sent to the
matrix in the decoder. (2., 3.) When it matches a bit set in the
CV in the matrix, the signal is sent to activate the output logic.
(4.) The output logic determines if the conditions are met to turn
the light on and then how it is to be operated. Like a ditch light
or whatever has been programmed in the control CV. (5.) If all conditions
are met, the light will turn on.
Key mapping is something that you should experiment
with to become familiar with how it operates.. If you have more
than one light, like headlight, strobe and Mars light, they can
all be turned on with one function key. More than one output can
be controlled by a single function key. That way you can turn on
all the lights with a single key. Handy if you are like me and forget
which keys on which locomotive operate the different lights.
Conclusion
There are a number of reasons why two decoders will do a job that
cannot be done with a single decoder. Newer, smaller decoders make
it easier to fit in more than one decoder in a locomotive. Using
more than one decoder lets you choose the best performance decoders
for your locomotives. If you have a locomotive with good motor control,
why not add a sound only decoder to complete the locomotive.
Connecting two or more locomotives together that
are kept together as one unit makes consisting easier. The units
can also be connected together with two pin connectors for more
reliable electrical pick up.
We welcome comments or
suggestions from readers; please write
or call.
|